OceanTec Electronics

We know what works.

 

GENERAL OCEANICS

 

Model 7000 Series Data Loggers

Water Monitoring Instruments

The Series 7000 data recording instruments are assembled from standard components to meet each customer's individual requirements.

An internal clock, re-settable by user, tags each data reading with the date and time at which it was taken.

The housing is our time-tested "hard coat anodized" aluminum cylinder with patented G.O. "spaghetti line" end cap locks. Housings are pressure rated to 5000 meters (sea water) when properly sealed.

Specifications

Time GMT: Internal Quartz Crystal Clock, Accuracy +/- 1.0 sec/day. User settable.

Temperature:

Pressure Sensor Ranges:

Pressure housing is limited to 5000 Meters.
Accuracy: 0.5% of range
Resolution: 0.1%
Accuracy (Quartz Sensor) +/- .01%
Resolution (Quartz Sensor) +/- 0.005%
Sampling Rates and Intervals are configured on screen with IBM/PC/AT.

Conductivity:

Direction:

Magnetic Flux Gate

Tilt Sensor

Pressure Case: (all instruments) 5,000 Meter (8,000 psi) anodized aluminum casing with o-ring end seals and the G.O. patented spaghetti line end cap locking systems.

Case Dimensions: Cylinder- 51.4 cm (20.25 in) x 10.5 cm diameter (4,125 in).

Instrument Weight: In Air- 6.9kg (15.17 lbs) maximum.

External Optional Temperature Probe comes with cable, to order.
Serial Output includes U/W Bulkhead connector; mating connector not included.
Factory installed Memory Cell.
EIA232 Cable is supplied with all instruments. Software for IBM XT, PC or AT, or compatibles.
All instruments equipped with Lithium D cells for up to one- year field life.
Optional alkaline battery pack available.