Pentad Hydrophone (P/N 923)



DESCRIPTION

SPECIFICATIONS

Vertical Directionality (5KHz)

Horizontal Directionality (10KHz)

CLICK ON GRAPHS ABOVE FOR LARGER VERSION


O V E R V I E W

The name Pentad comes from this hydrophones unique five wire interface. This hydrophone has been fully specified, tested, laboratory calibrated and operationally used for making acoustic measurements.


INTERFACE   SPECIFICATIONS

Sensitivity: -174.6 dBre1 V/uPa
Total Harmonic Distortion: -65 dB
Maximum hydrostatic pressure (Operational Depth): 1500 psi (1029m)
Frequency Response: 10 Hz to 20 kHz
Acoustic Noise Floor: 15 dB below Sea State 0 typical
Dynamic range: 160 dB (peak RMS to spectral)
Calibration Signal Input
Power Supply: 10v-30v
Hydrophone removal accomplished with single set screw